Micro Data Center Solutions


Micro Data Center Solutions


Webb offers revolutionary data management solutions with our innovative indoor, outdoor, and container micro data centres. Our indoor micro data centres seamlessly integrate into workspaces, providing flexible and efficient solutions. Outdoor micro data centres thrive in diverse environments, offering robust data management for outdoor applications. The containerized micro datacenters are ideal for rapid deployment and provide unparalleled mobility and scalability in remote locations or for organizations with dynamic data requirements.


Indoor Micro Data Center Racks

  • Rack level cooling, cold and hot aisle isolation, and PUE values as low as 1.3
  • Fully enclosed design, dust and noise reduction, IP rating up to IP55
  • Cabinets are covered with insulating material to prevent condensation
  • The cabinets are equipped with a standard emergency pop up door system, which can automatically open the front and rear doors in the event of       a fire or when sensors detect extreme temperatures
  • Supports remote access via web, app, and centralised monitoring, with compatibility for monitoring protocols such as Modbus TCP, SNMPv1/v2,       and BACnet.

Micro Data Center with Premium Cooling

3kW - 6kW Micro data center fully integrated with closed rack, package cooling, UPS, battery, power distribution, security, monitoring and fire systems. No complex piping of remote condenser installation.

Micro Data Center with Row Cooling

5kW - 10kW Micro data center fully integrated with closed rack, package cooling, UPS, battery, power distribution, security, monitoring and fire systems. No complex piping of remote condenser installation.

Micro Data Center with Rack Split Cooling

3kW - 10kW Micro data center fully integrated with closed rack, rack mount cooling, UPS, battery, power distribution, security, monitoring and fire systems. Modular rack cooling flexible for rack oriented MDC plan, expansion and deployment.

Micro Data Center with Row and Split Cooling

6kW - 20kW Micro data center fully integrated with closed rack, split cooling, UPS, battery, power distribution, security, monitoring and fire systems. Row cooling seamless integration with rack row and capacity expansion.





Indoor Micro Data Center Row Series



Micro Data Center Modular Series






Outdoor Micro Data Center Racks


Single Rack Micro Data Center with Rack Cooling

Micro data center fully integrated with single rack space, rack cooling, AC/DC power, battery, power distribution, security, monitoring and fire systems. IP55 protection and thermal insulation for outdoor deployment. Operating temperature range: -35°C ~ +45°C ambient.

Dual Rack Micro Data Center with Rack Cooling

Micro data center fully integrated with dual rack space, rack cooling, AC/DC power, battery, power distribution, security, monitoring and fire systems. IP55 protection and thermal insulated for outdoor deployment. Operating temperature range: -35°C ~ +45°C ambient.

Dual Rack Micro Data Center with Row Cooling

Micro data center fully integrated with dual rack space, in row cooling, AC/DC power, battery, power distribution, security, monitoring and fire systems. IP55 protection and thermal insulated for outdoor deployment. Operating temperature range: -35°C ~ +45°C ambient.

Triple Rack Micro Data Center with Rack Cooling

Micro data center fully integrated with triple rack space, rack cooling, AC/DC power, battery, power distribution, security, monitoring and fire systems. IP55 protection and thermal insulated for outdoor deployment. Operating temperature range: -35°C ~ +45°C ambient.








Containerized Racks

Webb Containerized rack series include single and dual container data centres. They are all-in-one micro data centres fully integrated with standard racks, wall mounted cooling systems, AC/DC power, batteries, power distribution, security, and monitoring fire systems. They are IP55-protected and thermally insulated for global deployment.


Options include: 10F Container data centre, 20F Container data centre, 40F Container data centre and Dual container data centres which are assembled from 2 or more containers. Ambient temperature: -35°C to +55°C







*Specifications are subject to change without notice based on technical recommendations and related product enhancements